A small valve sits between the engines of an ATR turboprop and the rubber boots on its wings and tail. If it quietly fails on a sunny day, nobody notices. If it is still broken when the aircraft flies into icing cloud, the European Union Aviation Safety Agency says the result could be a loss of control.
On Monday 16 November 2026, EASA issued airworthiness directive 2026-0219, ordering operators of older-generation and current ATR 42 and ATR 72 aircraft to test each ATR de-icing valve far more often. For the most common modified aircraft, the maximum interval between checks drops from 1,050 flight hours to 160. The rule takes effect on 30 November.
Informations clés
- Directive: EASA AD 2026-0219 (supersedes AD 2025-0011 of 10 January 2025)
- Issued: Monday 16 November 2026
- Efficace: 30 November 2026
- Aéronef: ATR 42-200/-300/-320/-400/-500 and ATR 72-101/-102/-201/-202/-211/-212/-212A, all serial numbers
- Part: De-icing system Pressure Regulator and Shut-Off Valve (PRSOV)
- New check intervals: 160 FH (modified ATR 42-400/-500 and ATR 72), 210 FH (unmodified), 190 FH (ATR 42-200/-300/-320)
- Previous limits: 1,050 FH, 700 FH and 650 FH respectively
- Stated risk: An undetected dormant valve failure combined with icing could ultimately cause loss of control
- Comments: Accepted until 14 December 2026
What the valve does
The part in question is the Pressure Regulator and Shut-Off Valve, or PRSOV. ATR wings and tailplanes use pneumatic de-icing boots: strips of rubber along the leading edges that inflate and deflate to crack off ice that has formed. The PRSOV regulates the engine bleed air that feeds that system, and shuts it off when it is not needed.

The danger EASA describes is a “dormant” failure. A faulty valve gives no sign of trouble in clear air, because the boots are not being used. The fault only matters when the crew switches on the de-icing in icing conditions, and that is exactly when it can no longer be fixed. A regular functional check on the ground is the only way to find it in time. For the bigger picture of boots, bleed air and fluids, see Afterburner’s guide to how aircraft de-icing and anti-icing work.
From 1,050 hours to 160
This is the second time in under two years that EASA has tightened the rule. Its earlier directive, AD 2025-0011, dated 10 January 2025 and effective from 24 January that year, first made the repetitive PRSOV checks mandatory. EASA says the new AD came after updated results from the valve supplier’s failure modes and effects analysis, reflected in ATR’s system safety assessment, showed the interval had to be cut again.
ATR revised its maintenance instructions, Airworthiness Operators Message 2024/12, to Issue 6 on 26 October 2026. The new AD makes that revision mandatory and splits the fleet into three groups. Aircraft carrying ATR modification 06076 from the factory, or the equivalent service bulletin applied later, are hit hardest: their limit falls from 1,050 to 160 flight hours, a cut of roughly 85 percent.
Fly with Magnar walks through the ice and rain protection systems on ATR aircraft, including the pneumatic de-icing boots.
Unmodified ATR 42-400s, ATR 42-500s and ATR 72s go from 700 hours to 210. The original ATR 42-200, -300 and -320 drop from 650 hours to 190. To avoid grounding aircraft overnight, operators get some breathing room: the next check is due at the new interval or within 100 flight hours of the effective date, whichever is later, but never beyond the old limit.
If a check finds a problem, the fault has to be fixed before the next flight. Where ATR’s published instructions do not cover the fault, the operator must contact ATR for approved repair instructions and carry them out before the aircraft flies again.

Which aircraft are covered
The directive applies to every serial number of the ATR 42-200, -300, -320, -400 and -500 and the ATR 72-101, -102, -201, -202, -211, -212 and -212A. The ATR 72-212A is the certified designation behind the aircraft ATR marketed as the ATR 72-500 and the ATR 72-600, so the order reaches deep into today’s regional fleets, from island hoppers to Nordic winter routes. The type is compared with its Canadian rival in our ATR 72 vs Q400 guide.
EASA issued 2026-0219 as a final AD with a request for comments, meaning the rule applies first and consultation follows. Comments can be sent until 14 December 2026; a comment-response document will only be published if anyone writes in.
The pneumatic de-icing boots on an ATR 72 inflating and deflating on the engine air intake and the airframe.
What happens outside Europe
EASA is the certifying authority for ATR, the Franco-Italian manufacturer based in Toulouse, so its directives tend to travel. The US Federal Aviation Administration copied the first round: its AD 2025-24-09, effective 13 January 2026, required the same repetitive PRSOV tests on ATR 42 and ATR 72 aircraft on the US register.
Whether the FAA and other national authorities will adopt the new, shorter intervals had not been announced when this story was written.
For crews and passengers, the change will be invisible. For maintenance departments on a busy aircraft flying several hours a day, a check that used to come round every few months now comes round every few weeks. The point is simple: find the broken valve in a hangar, not in a cloud.
Sources: EASA Airworthiness Directive 2026-0219 and AD 2025-0011 (ad.easa.europa.eu), AeroTime, Federal Register (FAA AD 2025-24-09), Aviation Week, Fly with Magnar, Wikipedia (ATR 72; Ice protection system)
Header photo: Anna Zvereva / Wikimedia Commons, CC BY-SA 2.0




0 Comments